Your cart

Your cart is empty

Ultra Air Aerosol Plus project Pic Solution

Regular price €254,94 €212,45 -17%
Unit price
per

Air Projet Plus 2018 Pic Solution Medical Device Device for aerosol therapy. | Quiet and fast, therefore ideal for children| The design has been specially developed to make therapeutic treatment simpler and more practical thanks to the appliance rotation system and the connecting tube, which allow therapy to be carried out comfortably while following the child's movements.| Accessori included: AirSoft 2 in 1 mask, nasal fork, mouthpiece, connecting tube.| Equipped with an aerosol carry bag.| Directions for use For aerosol therapy treatment| Medical device according to directive 93/42 EEC| Amended by directive 2007/47/EC| Implemented with Legislative Decree no. 37 of 25-01-2010| Class IIa| EN 60601-1-2 compliance| EN 60601-1| CLEANING AND MAINTENANCE Before cleaning and maintaining the reservoir, switch off the appliance (if on) by pressing the power switch button (M) and remove the plug of the detachable power connection cable (L) from the socket and disconnect the connector of the detachable cable from the appliance.| Warning! Never immerse or wet the appliance in water or other liquids.| To clean any residue from the medication reservoir, use only a soft, clean cloth slightly dampened with warm water. Carry out una thorough cleaning of all surfaces of the medication reservoir (I), particularly in the areas where they intersect. Cleaning operations must be carried out at the end of each therapy session. Do not use cleaning agents that could damage the appliance.o.| Cleaning and maintenance of the accessori Separate all the accessori (mask, mouthpiece, fork and tube) used and rinse them under running water.| WARNING! Do not boil the mask. Cold disinfect the parts that come into contact with the patient using denatured alcohol. It is recommended to clean and check the integrity of the accessori before and after each use and to replace them if damaged.| Dry all components and the appliance thoroughly before storing it away.| Store the appliance in a cool, dry place away from light and heat sources.| Never use benzene, thinners or other flammable chemicals for cleaning. For una greater hygiene safety, never use the same accessori for more than one patient, but purchase a dedicated kit for each user.| Disposal In accordance with current regulations| Warnings for use Before use, carefully read and understand the information contained in this manual and keep it for future reference.| Appliance intended for aerosol therapy. Always follow the doctor's instructions on the type of medication to use, the dosage, frequency and duration of inhalations. Any use other than that for which the appliance is intended is to be considered improper and therefore dangerous; Pikdare cannot be held responsible for damage caused by improper, incorrect and/or unreasonable use or if the appliance is used in electrical systems that do not comply with current safety regulations.| After removing the appliance from the packaging, make sure it is intact, with no visible damage that may have been caused during transport. If in doubt, do not use the appliance and contact the Technical Assistance Centre PiC.| Keep packaging components (bags, box, etc.) out of the reach of children as they are potential sources of danger.| Before Before connecting the appliance, make sure that the rating data matches that of your electrical distribution network. The rating data is located on the bottom of the appliance.| If the appliance plug is incompatible with the mains socket, use certified adapters in accordance with the regulations in force in the individual countries.| To prevent overheating and damage to the appliance, it must be switched off for 30 minutes after every 15 minutes of operation.| Warning! Inadequate cooling of the appliance before reuse could result in excessive overheating, causing the thermal protection devices to activate.| Do not use the appliance in the presence of nitrous oxide, oxygen or flammable anaesthetic mixture with air.| Switch off the appliance and disconnect it from the mains after each use and before adding more medication.| Keep the appliance and the power cord away from hot surfaces.| Do not use the appliance while fa the bath or shower, or in a humid environment, or near tubs, sinks, washbasins and so on.| Never touch the appliance with wet or damp hands.| Never drop or immerse the appliance in water or other liquids. Should this happen, switch off the main system switch, unplug it, never use the appliance and contact technically qualified personnel.| Do not use the appliance if drowsy or sluggish.| Do not use the appliance in environments dove sprays have just been used: ventilate the room before proceeding with the therapy.| Do not block or obstruct the appliance's air openings.| Do not insert any object into the cooling openings.| Do not pull the power cord or the appliance itself to remove the plug from the socket.| If used by children or people with reduced physical or cognitive abilities, adequate supervision is required. The appliance contains small parts that may come loose and be accidentally swallowed. Children should be supervised to ensure that they do not play with the appliance.| Do not use fittings or accessori not provided for by the manufacturer.| Make sure that the appliance is positioned during use (and stored) on flat, stable surfaces to prevent tipping over.| During use, the supporting surface must be free of objects that may obstruct the correct airflow.| Never leave the cable plug inserted in the socket when the appliance is not operating or when it is unattended.| Before carrying out any cleaning or maintenance operation, disconnect the appliance from the power supply by unplugging it from the socket.| When you decide to no longer use this appliance, after unplugging it from the socket, it is recommended to make it inoperative by cutting the power cord. It is also recommended to make harmless those parts of the appliance that could constitute a danger, especially for children.| For the disposal of accessori subject to wear, refer to the regulations in force. Do not dispose of the appliance as normal household waste; use separate collection as electrical/electronic equipment (WEEE) as required by the current EC laws and directives.| This appliance must no longer be used if, after having suffered una fall, it appears damaged or deteriorated in any of its parts. If in doubt, contact the Technical Assistance Centre Pic .• In the event of a fault and/or malfunction of the appliance, switch it off by unplugging it from the power socket and contact only the Assistance Centre PiC. Do not attempt to open or tamper with the appliance.| Electromedical equipment requires special precautions regarding electromagnetic compatibility: install and put this appliance into service according to the electromagnetic compatibility information in the user manual.| Warning: portable and mobile RF communication equipment may affect electromedical equipment.| Warning: do not use the appliance near or stacked with other equipment.| Preparing and using the appliance Remove the appliance and the accessori from the packaging or from the aerosol carry bag;| WARNING! Carefully check the surface of the medicine tank and all components before each use. In the event of visible damage or breakage, do not use the appliance and contact the Technical Assistance Centre PiC;| Lift the lid of the medicine tank;| Put the medicine into the appropriate tank, following the doses recommended by the doctor or pharmacist;| The contents of the tank must never exceed the reference mark shown on the tank itself.| The maximum capacity of the medicine tank is 8 ml; any solution with a greater volume must be divided into multiple inhalations;| The minimum capacity of the medicine tank is 3 ml; a smaller volume of solution must be diluted with 7 saline solution, unless diverse otherwise specified in the instruction leaflet of the| medicine;| Close the tank lid again, checking that it is properly closed;| Choose the most suitable accessory for the therapy: mask, mouthpiece, nasal fork (applied parts); if in doubt, consult your doctor or pharmacist.| Ultrasonic Aerosol Device | FAST AND QUIET: an aerosol therapy device with ultrasonic technology, fast and quiet, with a compact DLS design| COMPLETE AND COMFORTABLE: thanks to the fast and quiet nebulisation, it is ideal for supporting breathing comfort| PRACTICAL TO USE: the distinctive design and ultrasonic technology make it immediately pronto to use and easy to use and clean in just a few steps after therapy| HIGH-FREQUENCY TECHNOLOGY: high-frequency sound waves spread through the liquid and break up the solution, turning it into a fine mist| INCLUDES: AirProjet Plus aerosol, connection tube, mouthpiece, fork, una soft “2 in 1” mask, which adapts easily to the face of adults and children, and a practical bag The silent aerosol for adults and children| Details Fast and quiet nebulisation | It offers una fast and quiet nebulisation: thanks to the internal ultrasonic system, AirProjet Plus takes little tempo to complete aerosol therapy and does not require water, only the medicine.| The ultrasonic system | Nebulisation occurs thanks to high-frequency sound waves that spread through the water and break up the solution, nebulising it.| Designed for those who want everything close at hand | The accessori make aerosol therapy more convenient and can be stored in una practical bag so you can take it with you when travelling, protecting it from knocks.| WHAT IS DLS DESIGN? It stands for Design Language Solution, the product development philosophy of Pic born from the needs of the people and inspired by the shapes of nature. Simplicity: the request from Italian families was clear, and we rose to the challenge with our usual enthusiasm and passion. The rounded shapes, the dominant white colour, the handles redesigned to be comfortable and intuitive, the clearly visible displays, the reduced number of buttons to favour ease of use and speed, the slim and reassuring silhouettes: these are just some of the improvements we have made to our products, now it’s up to you to experience them first-hand.| It is a CE 0068 Medical Device. Ministerial authorisation dated 12.10.2021| Read the warnings or instructions for use carefully.| Pack format with 1 piece.

Ultra Air Aerosol Plus project Pic Solution

Regular price €254,94 €212,45 -17%
Unit price
per
Fast shipping
Secure payment
 
(0 in cart)
Tax included.Shipping calculated at checkout.

You might also like

Air Projet Plus 2018 Pic Solution Medical Device Device for aerosol therapy. | Quiet and fast, therefore ideal for children| The design has been specially developed to make therapeutic treatment simpler and more practical thanks to the appliance rotation system and the connecting tube, which allow therapy to be carried out comfortably while following the child's movements.| Accessori included: AirSoft 2 in 1 mask, nasal fork, mouthpiece, connecting tube.| Equipped with an aerosol carry bag.| Directions for use For aerosol therapy treatment| Medical device according to directive 93/42 EEC| Amended by directive 2007/47/EC| Implemented with Legislative Decree no. 37 of 25-01-2010| Class IIa| EN 60601-1-2 compliance| EN 60601-1| CLEANING AND MAINTENANCE Before cleaning and maintaining the reservoir, switch off the appliance (if on) by pressing the power switch button (M) and remove the plug of the detachable power connection cable (L) from the socket and disconnect the connector of the detachable cable from the appliance.| Warning! Never immerse or wet the appliance in water or other liquids.| To clean any residue from the medication reservoir, use only a soft, clean cloth slightly dampened with warm water. Carry out una thorough cleaning of all surfaces of the medication reservoir (I), particularly in the areas where they intersect. Cleaning operations must be carried out at the end of each therapy session. Do not use cleaning agents that could damage the appliance.o.| Cleaning and maintenance of the accessori Separate all the accessori (mask, mouthpiece, fork and tube) used and rinse them under running water.| WARNING! Do not boil the mask. Cold disinfect the parts that come into contact with the patient using denatured alcohol. It is recommended to clean and check the integrity of the accessori before and after each use and to replace them if damaged.| Dry all components and the appliance thoroughly before storing it away.| Store the appliance in a cool, dry place away from light and heat sources.| Never use benzene, thinners or other flammable chemicals for cleaning. For una greater hygiene safety, never use the same accessori for more than one patient, but purchase a dedicated kit for each user.| Disposal In accordance with current regulations| Warnings for use Before use, carefully read and understand the information contained in this manual and keep it for future reference.| Appliance intended for aerosol therapy. Always follow the doctor's instructions on the type of medication to use, the dosage, frequency and duration of inhalations. Any use other than that for which the appliance is intended is to be considered improper and therefore dangerous; Pikdare cannot be held responsible for damage caused by improper, incorrect and/or unreasonable use or if the appliance is used in electrical systems that do not comply with current safety regulations.| After removing the appliance from the packaging, make sure it is intact, with no visible damage that may have been caused during transport. If in doubt, do not use the appliance and contact the Technical Assistance Centre PiC.| Keep packaging components (bags, box, etc.) out of the reach of children as they are potential sources of danger.| Before Before connecting the appliance, make sure that the rating data matches that of your electrical distribution network. The rating data is located on the bottom of the appliance.| If the appliance plug is incompatible with the mains socket, use certified adapters in accordance with the regulations in force in the individual countries.| To prevent overheating and damage to the appliance, it must be switched off for 30 minutes after every 15 minutes of operation.| Warning! Inadequate cooling of the appliance before reuse could result in excessive overheating, causing the thermal protection devices to activate.| Do not use the appliance in the presence of nitrous oxide, oxygen or flammable anaesthetic mixture with air.| Switch off the appliance and disconnect it from the mains after each use and before adding more medication.| Keep the appliance and the power cord away from hot surfaces.| Do not use the appliance while fa the bath or shower, or in a humid environment, or near tubs, sinks, washbasins and so on.| Never touch the appliance with wet or damp hands.| Never drop or immerse the appliance in water or other liquids. Should this happen, switch off the main system switch, unplug it, never use the appliance and contact technically qualified personnel.| Do not use the appliance if drowsy or sluggish.| Do not use the appliance in environments dove sprays have just been used: ventilate the room before proceeding with the therapy.| Do not block or obstruct the appliance's air openings.| Do not insert any object into the cooling openings.| Do not pull the power cord or the appliance itself to remove the plug from the socket.| If used by children or people with reduced physical or cognitive abilities, adequate supervision is required. The appliance contains small parts that may come loose and be accidentally swallowed. Children should be supervised to ensure that they do not play with the appliance.| Do not use fittings or accessori not provided for by the manufacturer.| Make sure that the appliance is positioned during use (and stored) on flat, stable surfaces to prevent tipping over.| During use, the supporting surface must be free of objects that may obstruct the correct airflow.| Never leave the cable plug inserted in the socket when the appliance is not operating or when it is unattended.| Before carrying out any cleaning or maintenance operation, disconnect the appliance from the power supply by unplugging it from the socket.| When you decide to no longer use this appliance, after unplugging it from the socket, it is recommended to make it inoperative by cutting the power cord. It is also recommended to make harmless those parts of the appliance that could constitute a danger, especially for children.| For the disposal of accessori subject to wear, refer to the regulations in force. Do not dispose of the appliance as normal household waste; use separate collection as electrical/electronic equipment (WEEE) as required by the current EC laws and directives.| This appliance must no longer be used if, after having suffered una fall, it appears damaged or deteriorated in any of its parts. If in doubt, contact the Technical Assistance Centre Pic .• In the event of a fault and/or malfunction of the appliance, switch it off by unplugging it from the power socket and contact only the Assistance Centre PiC. Do not attempt to open or tamper with the appliance.| Electromedical equipment requires special precautions regarding electromagnetic compatibility: install and put this appliance into service according to the electromagnetic compatibility information in the user manual.| Warning: portable and mobile RF communication equipment may affect electromedical equipment.| Warning: do not use the appliance near or stacked with other equipment.| Preparing and using the appliance Remove the appliance and the accessori from the packaging or from the aerosol carry bag;| WARNING! Carefully check the surface of the medicine tank and all components before each use. In the event of visible damage or breakage, do not use the appliance and contact the Technical Assistance Centre PiC;| Lift the lid of the medicine tank;| Put the medicine into the appropriate tank, following the doses recommended by the doctor or pharmacist;| The contents of the tank must never exceed the reference mark shown on the tank itself.| The maximum capacity of the medicine tank is 8 ml; any solution with a greater volume must be divided into multiple inhalations;| The minimum capacity of the medicine tank is 3 ml; a smaller volume of solution must be diluted with 7 saline solution, unless diverse otherwise specified in the instruction leaflet of the| medicine;| Close the tank lid again, checking that it is properly closed;| Choose the most suitable accessory for the therapy: mask, mouthpiece, nasal fork (applied parts); if in doubt, consult your doctor or pharmacist.| Ultrasonic Aerosol Device | FAST AND QUIET: an aerosol therapy device with ultrasonic technology, fast and quiet, with a compact DLS design| COMPLETE AND COMFORTABLE: thanks to the fast and quiet nebulisation, it is ideal for supporting breathing comfort| PRACTICAL TO USE: the distinctive design and ultrasonic technology make it immediately pronto to use and easy to use and clean in just a few steps after therapy| HIGH-FREQUENCY TECHNOLOGY: high-frequency sound waves spread through the liquid and break up the solution, turning it into a fine mist| INCLUDES: AirProjet Plus aerosol, connection tube, mouthpiece, fork, una soft “2 in 1” mask, which adapts easily to the face of adults and children, and a practical bag The silent aerosol for adults and children| Details Fast and quiet nebulisation | It offers una fast and quiet nebulisation: thanks to the internal ultrasonic system, AirProjet Plus takes little tempo to complete aerosol therapy and does not require water, only the medicine.| The ultrasonic system | Nebulisation occurs thanks to high-frequency sound waves that spread through the water and break up the solution, nebulising it.| Designed for those who want everything close at hand | The accessori make aerosol therapy more convenient and can be stored in una practical bag so you can take it with you when travelling, protecting it from knocks.| WHAT IS DLS DESIGN? It stands for Design Language Solution, the product development philosophy of Pic born from the needs of the people and inspired by the shapes of nature. Simplicity: the request from Italian families was clear, and we rose to the challenge with our usual enthusiasm and passion. The rounded shapes, the dominant white colour, the handles redesigned to be comfortable and intuitive, the clearly visible displays, the reduced number of buttons to favour ease of use and speed, the slim and reassuring silhouettes: these are just some of the improvements we have made to our products, now it’s up to you to experience them first-hand.| It is a CE 0068 Medical Device. Ministerial authorisation dated 12.10.2021| Read the warnings or instructions for use carefully.| Pack format with 1 piece.